B-63434EN/02 OPERATION 1.PARAMETER SETTING
- 79 -
30010 Node name: 1st character
30011 Node name: 2nd character
30012 Node name: 3rd character
30013 Node name: 4th character
30014 Node name: 5th character
30015 Node name: 6th character
30016 Node name: 7th character
30017 Node name: 8th character
30018 Node name: 9th character
30019 Node name: 10th character
[Data type] Byte
[Index number] Pa17
Set the equipment name of the local node one character for each
parameter in ASCII code.
30020 Start address of area 1 transmit data
[Data type] Word
[Valid data range] 0 - 511
[Index number] Pa11
30021 Area 1 transmit data size
[Data type] Word
[Valid data range] 0 - 512
[Index number] Pa12
30022 Start address of area 2 transmit data
[Data type] Word
[Valid data range] 0 - 8191
[Index number] Pa13
30023 Area 2 transmit data size
[Data type] Word
[Valid data range] 0 - 8192
[Index number] Pa14
30024 Token monitoring time
[Data type] Byte
[Unit of data] 1 msec
[Valid data range] 1 - 255
[Index number] Pa15
30025 Minimum allowable frame interval
[Data type] Byte
[Unit of data] 100 μsec