12
12.3 Alarms
756
8760
Program start number used when I/O Link β amplifier parameter data is
registered
[Data type] Word
[Valid data range]
0 to 9999
In accordance with the formula below, the correspondence
between a program number used for parameter file
registration and an I/O Link β amplifier is determined.
Setting of PRM8760 + (I/O Link β amplifier group
number10)
(Example) Example: When PRM8760 = 8000
D At read time
The parameters of an I/O Link β amplifier of group 1 are
registered with the CNC as a program of O8010.
D At write time
When a parameter file is written on the parameter screen of
an I/O Link β amplifier of group 1, the parameter file must be
registered with the CNC as a program of O8010.
When the memory card is selected as the input/output
destination, the file name is O8010.PMM.
12.3 Alarms
Two types of alarms are used:
D Alarms of the Power Mate CNC Manager
→Displayed on the message line of the Power Mate CNC Manager
screen
D Alarms of the I/O Link β amplifier
→On the alarm screen of the Power Mate CNC Manager, a number is
displayed.
→On the I/O Link β amplifier, an LED indication is provided.
If an alarm is issued on an I/O Link β amplifier, the group number of the I/O
Link β amplifier is displayed at the right end of the message line on the Power
Mate CNC Manager screen. The number of an alarm issued can be checked
on the alarm screen of the Power Mate CNC Manager.