19
19.1 Inputting/Outputting Data
900
READ
O0001 N00010
PROGRAM (NUM.) MEMORY (CHAR.)
USED : 60 3321
FREE : 2 429
O0010 O0001 O0003 O0002 O0555 O0999
O0062 O0004 O0005 O1111 O0969 O6666
O0021 O1234 O0588 O0020 O0040
>_
EDIT * * * * * * * * * * * * * 14:46:09
F SRH
[][][][][]
PUNCH DELETE (OPRT)
4 To specify a program number to be assigned to an input program, enter
address O, followed by the desired program number.
If no program number is specified, the program number in the file or on
the NC tape is assigned as is.
5 Press soft key [READ], then [EXEC].
The program is input with the program number specified in step 4
assigned.
To cancel input, press soft key [CAN].
To stop input prior to its completion, press soft key [STOP].
EXECCANSTOP
(3) Outputting programs
1 Press soft key [PRGRM] on the ALL IO screen.
2 Select EDIT mode. A program directory is displayed.
3 Press soft key [(OPRT)]. The screen and soft keys change as shown
below.
⋅ A program directory is displayed only in EDIT mode. In all other
modes, the ALL IO screen is displayed.
READ
O0001 N00010
PROGRAM (NUM.) MEMORY (CHAR.)
USED : 60 3321
FREE : 2 429
O0010 O0001 O0003 O0002 O0555 O0999
O0062 O0004 O0005 O1111 O0969 O6666
O0021 O1234 O0588 O0020 O0040
>_
EDIT * * * * * * * * * * * * * 14:46:09
F SRH
[][][][][]
PUNCH DELETE (OPRT)
4 Enter address O.
5 Enter a desired program number.
If –9999 is entered, all programs in memory are output.
To output a range of programs, enter O∆∆∆∆, OVVVV.. The programs
numbered from ∆∆∆∆ to VVVV are output.
When PRM3107#4(SOR) for sorted display is set to 1 on the program
library screen, programs are output in order, starting from those having
the smallest program numbers.