19. MAINTENANCE FUNCTION
911
PROG (OPRT)DIR +
DIRECTORY (M–CARD)
No. FILE NAME SIZE DATE
O0034 N00045
0001 O1000 123456 01/07/10
0002 O1001 118458 01/07/30
0003 O0002 113250 01/07/30
0004 O2000 173456 01/07/31
0005 O2001 113444 01/07/31
0006 O3001 118483 01/08/02
0007 O3300 111406 01/08/05
0008 O3400 112420 01/07/31
0009 O3500 117460 01/07/31
~ ~
5 Press soft key [(OPRT)].
DELETEPUNCHF SRH F READ N READ
6 Set the number of the desired file with soft key [DELETE], then press
soft key [EXEC]. The file is deleted, and the directory screen is
displayed again.
DIRECTORY (M–CARD)
No. FILE NAME COMMENT
O0034 N00045
0019 O1000 (MAIN PROGRAM)
0020 O1010 (SUBPROGRAM–1)
0021 O1020 (COMMENT )
0022 O1030 (COMMENT )
~ ~
File name O1020 is deleted.
When file number 21 is deleted
DIRECTORY (M–CARD)
No. FILE NAME COMMENT
O0034 N00045
0019 O1000 (MAIN PROGRAM)
0020 O1010 (SUBPROGRAM–1)
0021 O1020 (COMMENT )
0022 O1030 (COMMENT )
~ ~
File number 21 is assigned to the next file name.
19.1.5.6 Batch input/output with a memory card
(ALL I/O screen)
On the ALL IO screen, different types of data including part programs,
parameters, offset data, pitch error data, custom macros, and workpiece
coordinate system data can be input and output using a memory card; the
screen for each type of data need not be displayed for input/output.
Memory card ALL IO screen
²
³
Data item name
Part program
Parameter
Offset data
Pitch error data
Custom macro
Workpiece coordinate system
data (additional coordinate
systems)
PRM20=4