APPENDIXG. ALARM LIST
B–63004EN/02
828
Number ContentsMessage
5056 M–NET BOARD SYSTEM DOWN Transmit time–out error (parameter No. 177)
ROM parity error
CPU interruption detection of not listed above
5058 G35/G36 FORMAT ERROR A command for changing the major axis was specified during circular
threading. Alternatively, the leangth of the major axis was specified to
be 0.
5059 RADIUS IS OUT OF RANGE During circular interpolation, the center of the arc specified with I, J,
and K caused the radius to exceed nine digits.
5073 NO DECIMAL POINT A decimal point is not specified for a command for which a decimal
point must be specified.
5074 ADDRESS DUPLICATION ERROR The same address appears more than once in a block. Alternatively,
a block contains two or more G codes belonging to the same group.
5082 DATA SERVER ERROR Details are displayed on the data server message screen.
5134 FSSB : OPEN READY TIME OUT Initialization did not place FSSB in the open ready state.
5135 FSSB : ERROR MODE FSSB has entered error mode.
5136 FSSB : NUMBER OF AMPS IS
SMALL
In comparison with the number of controlled axes, the number of amplifi-
ers recognized by FSSB is not enough.
5137 FSSB : CONFIGURATION ERROR FSSB detected a configuration error.
5138 FSSB : AXIS SETTING NOT
COMPLETE
In automatic setting mode, axis setting has not been made yet.
Perform axis setting on the FSSB setting screen.
5139 FSSB : ERROR Servo initialization did not terminate normally.
The optical cable may be defective, or there may be an error in connec-
tion to the amplifier or another module.
Check the optical cable and the connection status.
5155 NOT RESTART PROGRAM BY G05 During servo leaning control by G05, an attempt was made to perform
restart operation after feed hold or interlock. This restart operation can-
not be performed. (G05 leaning control terminates at the same time.)
5195 DIRECTION CAN NOT BE JUDGED When the touch sensor with a single contact signal input is used in the
direct input B function for tool offset measurement values, the stored
pulse direction is not constant. One of the following conditions exists:
· The stop state exists in offset write mode.
· Servo off state
· The direction varies.
· Movement takes place simultaneously along two axes.
5197 FSSB : OPEN TIME OUT The CNC permitted FSSB to open, but FSSB was not opened.
5198 FSSB : ID DATA NOT READ Temporary assignment failed, so amplifier initial ID information could not
be read.
5199 FINE TORQUE SENSING
PARAMETER
A parameter related to the fine torque sensing function is illegal.
· The storage interval is invalid.
· An invalid axis number is set as the target axis.
Correct the parameter.
5212 SCREEN COPY : PARAMETER
ERROR
There is a parameter setting error. Check that 4 is set as the I/O channel.
5213 SCREEN COPY :
COMMUNICATION ERROR
The memory card cannot be used. Check the memory card. (Check
whether the memory card is write–protected or defective.)
5214 SCREEN COPY : DATA TRANSFER
ERROR
Data transfer to the memory card failed.
Check whether the memory card space is insufficient and whether the
memory card was removed during data transfer.