OPERATION
B–63094EN/02
11. SETTING AND DISPLAYING DATA
649
With this function, functions of the switches on the machine operator’s
panel can be controlled from the CRT/MDI panel.
Jog feed can be performed using numeric keys.
Procedure for displaying and setting the software operator’s panel
1 Press function key
OFFSET
SETTING
.
2 Press the continuous menu key
, then press chapter selection soft
key
[OPR].
3 The screen consists of several pages.
Press page key
PAGE
or
PAGE
until the desired screen is displayed.
OPERATOR’S PANEL O0000 N00000
MODE : MDI MEM EDIT HNDL JOG REF
STEP MULTI. : *1 *10 *100
RAPID OVRD. : 100% 50% 25% F0
JOG FEED : 2.0%
**************
FEED OVRD. : 100%
***
ACTUAL POSITION (ABSOLUTE)
X 0.000 Y 0.000
Z 0.000
>_
MDI **** *** *** 16:05:59
[ MACRO ] [ ] [ OPR ] [TOOLLF] [ (OPRT) ]
OPERATOR’S PANEL O0000 N00000
BLOCK SKIP : OFF J ON
SINGLE BLOCK : J OFF ON
MACHINE LOCK : OFF J ON
PROTECT KEY : J PROTECT RELEASE
FEED HOLD : J OFF
ACTUAL POSITION (ABSOLUTE)
X 0.000 Y 0.000
Z 0.000
S 0 T0000
MDI **** *** *** 16:05:59
[ MACRO ] [ ] [ OPR ] [ TOOLLF ] [ (OPRT) ]
11.4.10
Displaying and Setting
the Software
Operator's Panel
Procedure
Continuous menu key
MOPR