Use the connector connected to the lithium battery for an external battery.
Following the battery replacement procedure described above, replace the
standard lithium battery with an external battery in a battery case
(A02B–0236–C281).
CAUTION
1 Place the battery case (A02B–0236–C281) in such a
position that the battery can be replaced even while the
control unit is active.
2 The connector of the battery cable uses a simple lock
system. Fix the cable within an area of 50 cm from the
connector, removing tension on the cable. This is required
to prevent the connector from coming off because of the
weight of the cable or tension on the cable.
When using commercial
D–size alkaline dry cells
D General method