OPERATION
B–62754EN/01
11. SETTING AND DISPLAYING DATA
695
Displays common variables (#100 to #149 or #100 to #199, and #500 to
#531 or #500 to #999) on the CRT. When the absolute value for a common
variable exceeds 99999999, ******** is displayed. The values for
variables can be set on this screen. Relative coordinates can also be set
to variables.
Procedure for displaying and setting custom macro common variables
1 Press function key
OFFSET
SETTING
.
2 Press the continuous menu key
, then press chapter selection
soft key
[MACRO].The following screen is displayed:
NO. DATA NO. DATA
100 1000.000 108 0.000
101 0.000 109 40000.000
102 –50000.000 110 153020.00
103 0.000 111 0001.000
104 1238501.0 112 0.000
105 0.000 113 20000.000
106 0.000 114 0.000
107 0.000 115 0.000
ACTUAL POSITION (RELATIVE)
U0.000 W 0.000
VARIABLE O0001 N00000
> _ S 0 T0000
MDI **** *** *** 16:05:59
[ NO.SRH ][ ][ INP.C. ][ ][ INPUT ]
3 Move the cursor to the variable number to set using either of the
following methods:
– Enter the variable number and press soft key
[NO.SRH].
– Move the cursor to the variable number to set by pressing page keys
PAGE
and/or
PAGE
and cursor keys , , , and/or .
4 Enter data with numeric keys and press soft key
[INPUT].
5 To set a relative coordinate in a variable, press address key
X
or
Z
, then press soft key [INP.C.].
6 To set a blank in a variable, just press soft key
[INPUT]. The value
field for the variable becomes blank.
11.4.12
Displaying and Setting
Custom Macro
Common Variables
MACRO
Continuous menu key