B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 215 -
5020 Device number for a reader/punch attached to JD5C on the additional-axis
board
[Input type] Setting input
[Data type] Integer
[Valid data range] 1 to 6
This parameter specifies the device number for a reader/punch
attached to connector JD5C.
The specification data numbers for devices corresponding to
reader/punch device numbers 1 to 6 are specified in parameter Nos.
5100 to 5162.
5021 Device number for a reader/punch attached to JD6B on the additional-axis
board
[Input type] Setting input
[Data type] Integer
[Valid data range] 1 to 6
This parameter specifies the device number for a reader/punch
attached to connector JD6B.
The specification data numbers for devices corresponding to
reader/punch device numbers 1 to 6 are specified in parameter Nos.
5100 to 5162.
#7 #6 #5 #4 #3 #2 #1 #0
5040 DSW
[Input type] Parameter input
[Data type] Bit
#0 DSW When an error occurs in a data server operation (excluding read and
punch operations) :
0: A BG alarm is issued.
1: A warning is issued.
#7 #6 #5 #4 #3 #2 #1 #0
5042 MNC
[Input type] Parameter input
[Data type] Bit
NOTE
After this parameter has been set, the power must be of
turned off then back on for the setting to become
effective.
#0 MNC Specifies whether to perform DNC operation and external device
subprogram calls from a memory card.
0: Do not perform these operations.
1: Perform these operations.