4.DESCRIPTION OF PARAMETERS B-63790EN/01
- 390 -
#7 #6 #5 #4 #3 #2 #1 #0
7617 DN
[Input type] Setting input
[Data type] Bit
#3 DNA Specifies whether to issue an alarm if the tool number (pot number)
specified by the tool data deletion command (G10L72) cannot be
found.
0: Issue an alarm (SR422) .
1: Do not issue an alarm, ignoring the deletion command of the
block.
#7 #6 #5 #4 #3 #2 #1 #0
7618 TM2 TM1 TM0
[Input type] Parameter input
[Data type] Bit
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
#0 TM0
#1 TM1
#2 TM2 This parameter specifies data distribution time in msec for binary
statement input operation. In binary statement input operation through
REMOTE BUFFER, set these parameters according to the following
table.
TM2 TM1 TM0
Time required for distributing
data at binary statement inputs
100 1msec
0 0 1 2 msec
0 1 0 4 msec
0 0 0 8 msec
0 1 1 16 msec
#7 #6 #5 #4 #3 #2 #1 #0
7620 MO
MOP
[Input type] Parameter input
[Data type] Bit
#3 MOP Specifies whether to output M, S, T, and B codes before a block to be
restarted is found at program restart time, then the tool is moved to
the machining restart position.
0: Do not output M, S, T, and B codes (the overstore mode is
disabled) .
1: Output M, S, T, and B codes (the overstore mode is enabled) .