4.2.3 On Delay Timer
4.2.3.1 TMR_THOUS(address, pv)
The standard timer increments while there is an accumulator present and resets to 0 when the accumulator is removed.
address: The first of three consecutive word registers. Word 1 - Current Value 'cv', Word 2 - Preset Value 'pv', Word 3
- Control Word.
pv: INT variable or constant (0 - 32,767); preset value in thousandths of second.
4.2.3.2 TMR_HUNDS(address, pv)
The standard timer increments while there is an accumulator present and resets to 0 when the accumulator is removed.
address: The first of three consecutive word registers. Word 1 - Current Value 'cv', Word 2 - Preset Value 'pv', Word 3
- Control Word.
pv: INT variable or constant (0 - 32,767); preset value in hundredths of second.
4.2.3.3 TMR_TENTHS(address, pv)
The standard timer increments while there is an accumulator present and resets to 0 when the accumulator is removed.
address: The first of three consecutive word registers. Word 1 - Current Value 'cv', Word 2 - Preset Value 'pv', Word 3
- Control Word.
pv: INT variable or constant (0 - 32,767); preset value in tenths of second.
4.2.3.4 TMR_SECS(address, pv)
The standard timer increments while there is an accumulator present and resets to 0 when the accumulator is removed.
address: The first of three consecutive word registers. Word 1 - Current Value 'cv', Word 2 - Preset Value 'pv', Word 3
- Control Word.
pv: INT variable or constant (0 - 32,767); preset value in one second.
4.2.3.5 TMR_TENSEC(address, pv)
The standard timer increments while there is an accumulator present and resets to 0 when the accumulator is removed.
address: The first of three consecutive word registers. Word 1 - Current Value 'cv', Word 2 - Preset Value 'pv', Word 3
- Control Word.
pv: INT variable or constant (0 - 32,767); preset value in ten seconds.
4.2.3.6 TMR_MIN(address, pv)
The standard timer increments while there is an accumulator present and resets to 0 when the accumulator is removed.
address: The first of three consecutive word registers. Word 1 - Current Value 'cv', Word 2 - Preset Value 'pv', Word 3
- Control Word.
pv: INT variable or constant (0 - 32,767); preset value in one minute.
For more details, see LD Functions.
Note: IL and LD functions are generally the same, with some differences in data types for operands.