FANUC PMC-MODEL SD7
Programming Manual
01 01.11.26
Hanaoka
New
A-78550E
EDIT DATE DESIG.
DESCRIPTION
306/
316
TITLE
DRAW.NO.
FILE NUMBER CAN NOT SELECTED The file number cannot be selected.
Action: If the file does not exist, the key entry is invalid. If
this error occurs even when the cursor is placed at a file name,
contact the FANUC service center.
INPUT FILE NUMBER IS NOT EXIST The entered file number is not present. The entered number
exceeds the total number of files.
Action: Check the total number of files on the list screen.
FILE NUMBER IS RESTRICTED TO
”128”
A value up to 128 can be entered as the file number.
Action: Enter a numeric value not exceeding 128.
INTERNAL ERROR (xxxxxxxxxx) An error due to an internal factor occurred. Details on the
error are displayed in parentheses.
Action: Contact the FANUC service center, and report the
displayed message correctly.
- Error messages displayed during flash ROM I/O operation
Displayed error message Meaning and action
NOT IN EMG STOP MODE The system is not in the emergency stop state.
Action: Place the system in the emergency stop state.
INVALID LADDER PROGRAM The transfer program is illegal.
Action: Check the program.
DIFFERENCE FOUND A file comparison detected a mismatch.
FLASH ROM IS LOCKED BY OTHER
FUNCTION.
Another PMC user is using the flash ROM.
Action: Wait until the PMC user completes processing, then
retry.
INTERNAL ERROR (xxxxxxxxxx) An error due to an internal factor occurred. Details on the
error are displayed in parentheses.
Action: Contact the FANUC service center, and report the
displayed message correctly.
- Error messages displayed during floppy cassettes, handy files or other input/output devices I/O operation.
Displayed error message Meaning and action
BAD PMC PARAMETER FORMAT Specified file is not PMC parameter format.
Action: Specify file of PMC parameter format, or check the
contents of the file.
BAD HANDY FILE FORMAT Specified file is not handy file format.
Action: Specify file of handy file format, or check the
contents of the file.
UNKNOWN FILE FORMAT Can not recognize the format of specified file.
Action: Specify file of recognizable format such as PMC
parameter format, or check the contents of the file.
FILE NAME OR FILE NUMBER IS
REQUIRED
Need file name or file number to identify file to read,
compare, or delete.
Action: Specify file name or file number for the operation.
COMMUNICATION TIMEOUT Communication with the I/O device has been timeout.
Action: Check the communication parameters such as baud
rate, and retry to communicate.