Changing of the European specification main breaker for FANUC LASER C2000-E & C4000-E
1. Outline
In the European specification (EUR) of FANUC LASER C2000-E & C4000-E, it changes the terminal
shape specification of the main breaker as well as a domestic specification The terminal for the cable
connection changes from the Box Terminal to the Screw Terminal by this changing. Therefore, please
connect the cable by using the recommended solderless terminal of each breaker that shows in the
following.
2. Changing Model
EUR specification of Model C2000-E, C4000-E
3. Details of changing contents
3-1. Specification of main breaker
(1) C2000-ERated current150A
Type : EA203C/150(made by Fuji Electric Co., Ltd.)
FANUC purchase spec. ; A60L-0001-0460#N150JH1
Recommended solderless terminal
Cable size
Type Name of recommended solderless terminalMaker
38mm
2
38-S8J.S.T Mfg Co., Ltd.
R38-8SNICHFU Terminal Industries CO., Ltd.
50mm
2
R60-8J.S.T Mfg Co., Ltd.
R60-8NICHFU Terminal Industries CO., Ltd.
Maker's recommended torque10.5[Nm]
(2) C4000-ERated current 225A (Rated current is changed from 200A to 225A.)
Type : EA203C/225(made by Fuji Electric Co., Ltd.)
FANUC purchase spec. ; A60L-0001-0460#N225JH1
Recommended solderless terminal
Cable size
Type Name of recommended solderless terminalMaker
100mm
2
CB100-S8J.S.T Mfg Co., Ltd.
CB100-8DAIDO Solderless Terminal Industries CO., Ltd.
150mm
2
CB150-S8J.S.T Mfg Co., Ltd.
CB150-8DAIDO Solderless Terminal Industries CO., Ltd..
Maker's recommended torque10.5[Nm]
(3) Shape sizeBoth C2000-E and C4000-E are the same shape.
Before
After

Contents Summary of Changing of the European Specification Main Breaker for FANUC LASER C2000-E & C4000-E Additional Manual

  • Page 1Changing of the European specification main breaker for FANUC LASER C2000-E & C4000-E 1. Outline In the European specification (EUR) of FANUC LASER C2000-E & C4000-E, it changes the terminal shape specification of the main breaker as well as a domestic specification The terminal for the cable connec
  • Page 23-2. Changing of terminal for cable connection(All models of EUR specification are the Screw Terminal specification as well as a domestic specification. ) Please connect cable to use the recommended solderless terminal for each breaker, because it changes the specification from a past Box Terminal t
  • Page 3Because the short-circuit interception capacity of the main breaker changes, the sticker is changed as shown in the figure below. Breaker Handle Sticker 【Before】 【After】 4. Application MODEL Application C2000-E Applied from the manufacturing in August,2005 C4000-E Applied from the manufacturing in S