B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 111 -
1820 Command multiplier for each axis (CMR)
NOTE
When this parameter has been set, the power must
be turned off before operation is continued.
[Data type] Byte axis
Set a command multiplier indicating the ratio of the least
command increment to the detection unit for each axis.
Least command increment = detection unit × command multiplier
Relationship between the increment system and the least command
increment
(1) T series
Least input increment
Least
command
increment
0.001 mm (diameter specification) 0.0005 mm Millimeter
input
0.001 mm (radius specification) 0.001 mm
0.0001 inch (diameter specification) 0.0005 mm
Millimeter
machine
Inch input
0.0001 inch (radius specification) 0.001 mm
0.001 mm (diameter specification) 0.00005 inch Millimeter
input
0.001 mm (radius specification) 0.0001 inch
0.0001 inch (diameter specification) 0.00005 inch
Inch
machine
Inch input
0.0001 inch (radius specification) 0.0001 inch
IS-B
Rotation axis 0.001 deg 0.001 deg
0.0001 mm (diameter specification) 0.00005 mm Millimeter
input
0.0001 mm (radius specification) 0.0001 mm
0.00001 inch (diameter specification) 0.00005 mm
Millimeter
machine
Inch input
0.00001 inch (radius specification) 0.0001 mm
0.0001 mm (diameter specification) 0.000005 inch Millimeter
input
0.0001 mm (radius specification) 0.00001 inch
0.00001 inch (diameter specification) 0.000005 inch
Inch
machine
Inch input
0.00001 inch (radius specification) 0.00001 inch
IS-C
Rotation axis 0.0001 deg 0.0001 deg
(2) M series
Least input increment and least command incrementIncrement
system
IS-A IS-B IS-C Units
Millimeter
machine
0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
Setting command multiply (CMR), detection multiply (DMR), and the
capacity of the reference counter