4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 148 -
REV The actual speed in feed per revolution mode is displayed in:
0 : MM/MIN or INCH/MIN.
1 : MM/REV or INCH/REV.
SOR Display of the program directory
0 : Programs are listed in the order of registration.
1 : Programs are listed in the order of program number.
MDL Display of the modal state on the program display screen
0 : Not displayed
1 : Displayed (only in the MDI mode)
#7 #6 #5 #4 #3 #2 #1 #0
3108 JSP SLM WCI PCT
[Data type] Bit
PCT On the program check screen, T code displayed
0 : is a T code specified in a program (T).
1 : is a T code specified by the PMC (HD. T/NX. T)
WCI On the workpiece coordinate system screen, a counter input is:
0 : Disabled.
1 : Enabled.
SLM The spindle load meter is:
0 : Not displayed.
1 : Displayed.
>_ Sxxxxx Lxxx%
EDIT *** *** *** 12:34:56
[ ] [ ] [ ] [ ] [ ]
Display of the
spindle load meter
NOTE
1 This parameter is enabled only when the DPS
parameter (bit 2 of parameter No.3105) is set to 1.
2 This is valid only for serial spindles.
JSP On the current position display screen and program check screen, jog
feed is:
0 : Not displayed.
1 : Displayed.
NOTE
In manual operation mode, the jog feedrate is
displayed. In automatic operation mode, the dry run
feedrate is displayed. In each case, the feedrate to
which a manual feedrate override has been applied
is displayed.
JOG F 8000 PART COUNT 15
RUN TIME 1H17M CYCLE TIME 1H15S
ACT.F 1000 MM/M
MEM STRT MTN *** 12:34:59
[ ] [ ] [ ] [ ] [ ]
Jog
feedrate