4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 168 -
3294 Start number of tool offset values whose input by MDI is disabled
3295
Number of tool offset values (from the start number) whose input by MDI is
disabled
[Data type] Word
To prevent tool offset values from being changed by MDI key input
operation using bit 0 (WOF) of parameter No. 3290 and bit 1 (GOF)
of parameter No. 3290, set the inhibited range in this parameter.
Set the start offset number of the tool offset values to be protected in
parameter No. 3294 and the number of tool offset values from the start
in parameter No. 3295.
When 0 or a negative value is set in parameter No.3294 or parameter
No.3295, no modification of the tool offset values is allowed.
When the value set with parameter No.3294 is greater than the
maximum tool offset count, no modification is allowed.
[Example]
The following setting disables the modification of both the tool
geometry compensation values and tool wear compensation
values corresponding to offset numbers 51 to 60:
Bit 1 (GOF) of parameter No.3290=1 (Disables tool offset value
modification.)
Bit 0 (WOF) of parameter No.3290=1 (Disables tool wear
compensation value modification.)
Parameter No.3294 = 51
Parameter No.3295 = 10
If bit 0 (WOF) of parameter No.3290 is set to 0, the modification
of the tool offset values alone is disabled. The tool wear
compensation values may be modified.
#7 #6 #5 #4 #3 #2 #1 #0
3301 HDC HCG HCA HCC
[Data type] Bit
HCC In the VGA-compatible mode display,
0 : A 256-color bit map data of the screen hard copy is created.
1 : A 16-color bit map data of the screen hard copy is created.
HCA An alarm message related to hard copy is:
0 : Not displayed.
1 : Displayed.
HCG In a monochrome bit map,
0 : Black and white are not inverted. (same as the screen image)
1 : Black and white are inverted.
HDC A screen hard copy is:
0 : Not provided.
1 : Provided.