4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 272 -
Positional deviation limit imposed during spindle movement in rigid tapping
using the second spindle
5351
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed
during spindle movement in rigid tapping using the second spindle.
NOTE
This parameter is enabled when the SPR
parameter (bit 1 of parameter No.5204) is set to 1.
Positional deviation limit imposed while the tapping axis is stopped in rigid
tapping using the second spindle
5352
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed
while the tapping axis is stopped in rigid tapping using the second
spindle.
NOTE
This parameter is enabled when the SPR
parameter (bit 1 of parameter No.5204) is set to 1.
Positional deviation limit imposed while the spindle is stopped in rigid
tapping using the second spindle
5353
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed
while the spindle is stopped in rigid tapping using the second spindle.
NOTE
This parameter is enabled when the SPR
parameter (bit 1 of parameter No.5204) is set to 1.