B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 297 -
4.31 PARAMETERS OF SKIP FUNCTION
#7 #6 #5 #4 #3 #2 #1 #0
SKF SRE SLS HSS MIT SK0 GSK
6200
SKF SRE SLS HSS SK0
[Data type] Bit
GSK In skip cutting (G31), the skip signal SKIPP <G006#6> is:
0 : Not used as a skip signal.
1 : Used as a skip signal.
SK0 This parameter specifies whether the skip signal is made valid under
the state of the skip signal SKIP <X004#7> and the multistage skip
signals <X004#0-7> (for the T series only).
0 : Skip signal is valid when these signals are 1.
1 : Skip signal is valid when these signals are 0.
MIT In skip cutting (G31), the tool compensation measurement value direct
input B signals +MIT1, -MIT1, +MIT2, and -MIT2 <X004#2-5> are :
0 : Not used as skip signals.
1 : Used as skip signals.
HSS 0 : The skip function does not use high-speed skip signals.
1 : The skip function uses high-speed skip signals.
SLS 0 The multi-step skip function does not use high-speed skip signals
while skip signals are input.
1 : The multi-step skip function uses high-speed skip signals while
skip signals are input.
SRE When a high-speed skip signal is used:
0 : The signal is considered to be input at the rising edge (0#1).
1 : The signal is considered to be input at the falling edge (1#0).
SKF Dry run, override, and automatic acceleration/deceleration for G31
skip command
0 : Disabled
1 : Enabled
#7 #6 #5 #4 #3 #2 #1 #0
6201 SPE IGX TSA TSE SEB SEA
[Data type] Bit
SEA When a high speed skip signal goes on while the skip function is used,
acceleration/deceleration and servo delay are:
0 : Ignored.
1 : Considered and compensated (type A).
SEB When a high speed skip signal goes on while the skip function is used,
acceleration/deceleration and servo delay are:
0 : Ignored.
1 : Considered and compensated (type B).