B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 325 -
4.38 PARAMETERS OF MANUAL OPERATION AND
AUTOMATIC OPERATION
#7 #6 #5 #4 #3 #2 #1 #0
7001 MIN
[Data type] Bit
MIN The manual intervention and return function is:
0 : Disabled.
1 : Enabled.
7015 Least command increment setting for jog feed
[Data type] Word
[Unit of data]
Input increment IS-A IS-B IS-C Unit
Metric machine 0.01 0.001 0.0001 mm
Inch machine 0.001 0.0001 0.00001 inch
Rotation axis 0.01 0.001 0.0001 deg
[Valid data range] 0 to 10000
This parameter sets the least command increment for jog feed when
PMC signal JGUNIT <G0023#0> is set to 1. If the setting of this
parameter is 0, a value of 1 is recognized.
#7 #6 #5 #4 #3 #2 #1 #0
7050
MI1 MI0
NOTE
After setting this parameter, turn off the power.
Then, turn the power back on to enable the setting.
[Data type] Bit
MI0, MI1 Set this parameter as indicated below.
MI1 MI0
When the servo FAD function is not used in AI advanced
preview control or AI contour control
0 1
When the servo FAD function is used in AI advanced preview
control or AI contour control
0 0