4.DESCRIPTION OF PARAMETERS B-64120EN/01
- 346 -
#7 #6 #5 #4 #3 #2 #1 #0
8002 FR2 FR1 PF2 PF1 F10 SUE DWE RPD
[Data type] Bit
RPD Rapid traverse rate for PMC-controlled axes
0 : Feedrate specified with parameter No.1420
1 : Feedrate specified with the feedrate data in an axis control
command
DWE Minimum time which can be specified in a dwell command in PMC
axis control when the increment system is IS-C
0 : 1 ms
1 : 0.1 ms
SUE Whether acceleration/deceleration is performed for an axis that is
synchronized with external pulses, for external pulse synchronization
commands in PMC axis control
0 : Performed (exponential acceleration/deceleration)
1 : Not performed
F10 Least increment for the feedrate for cutting feed (per minute) in PMC
axis control
F10 Millimeter input Inch input
0 1 mm/min 0.01 inch/min
1 10 mm/min 0.1 inch/min
PF1, PF2 Set the feedrate unit of feed per minute in PMC axis control
PF2 PF1 Feedrate unit
0 0 1/1
0 1 1/10
1 0 1/100
1 1 1/1000
FR1, FR2 Set the feedrate unit for feed per rotation for an axis controlled by the
PMC.
FR2 FR1 Millimeter input Inch input
0 0
1 1
0.0001 mm/rev 0.000001 inch/rev
0 1 0.001 mm/rev 0.00001 inch/rev
1 1 0.01 mm/rev 0.0001 inch/rev
#7 #6 #5 #4 #3 #2 #1 #0
8003 PAX PIM
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Bit
PIM Specifies whether to cause an inch/metric input to affect the linear axis
that is subjected only to PMC axis control (see the parameter
No.1010), as follows:
0: To affect.
1: Not to affect.