B-64120EN/01 4.DESCRIPTION OF PARAMETERS
- 35 -
NOTE
1 When bit 1 (DLZ) of parameter No. 1002 is 0, DLZx
is enabled. When bit 1 (DLZ) of parameter No.
1002 is 1, DLZx is disabled, and the function for
setting the reference position without dogs is
enabled for all axes.
2 Do not set this parameter for the Cs contour control
axis or spindle positioning axis.
HJZx When a reference position is already set:
0 : Manual reference position return is performed with deceleration
dogs.
1 : Manual reference position return is performed using rapid
traverse without deceleration dogs, or manual reference position
return is performed with deceleration dogs, depending on the
setting of bit 7 (SJZ) of parameter No.0002.
NOTE
When the function (see bit 1 (DLZ) of parameter
No. 1002) for setting the reference position without
dogs is used, positioning to a reference position is
always performed using rapid traverse in reference
position return after establishment of the reference
position, regardless of the setting of HJZ.
EDPx External deceleration signal in the positive direction for each axis
0 : Valid only for rapid traverse
1 : Valid for rapid traverse and cutting feed
EDMx External deceleration signal in the negative direction for each axis
0 : Valid only for rapid traverse
1 : Valid for rapid traverse and cutting feed