E.PARAMETERS APPENDIX B-66264EN/01
- 102 -
NOTE
When using a system with vertical soft keys, use bit
1 (KY100) of compile parameter No. 9160.
# 6 PTCH In macro variable output (G338), an EOB is output as:
0: LF.
1: LF CR CR.
#7 #6 #5 #4 #3 #2 #1 #0
9004 CUTLG
[Data type] Bit
# 7 CUTLG Cutting distance accumulation/preset (#8554) is:
0: Disabled.
1: Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
9005 AX4CL AX3CL AX2CL AX1CL
9008 AX8CL AX7CL AX6CL AX5CL
9164 X16CL X15CL X14CL X13CL X12CL X11CL X10CL X09CL
9165 X24CL X23CL X22CL X21CL X20CL X19CL X18CL X17CL
[Data type] Bit
Special macro call using an axis address is:
0: Disabled.
1: Enabled.
An axis is selected with the corresponding bit as follows:
No. 9005 # 0 AX1CL 1st axis
# 1 AX2CL 2nd axis
# 2 AX3CL 3rd axis
# 3 AX4CL 4th axis
No. 9008 # 0 AX5CL 5th axis
# 1 AX6CL 6th axis
# 2 AX7CL 7th axis
# 3 AX8CL 8th axis
No. 9164 # 0 X09CL 9th axis
# 1 X10CL 10th axis
:
# 7 X16CL 16th axis