B--63003EN--1/02
15. PMC CONTROL FUNCTION
1251
Kind of data accessed by external data input
E
SEEE
EEEE
ED15 to ED0
o.
tem
T
B
A
6
A
5
A
4
A
3
A
2
A
1
A
0
15141312 1110 9 8 7654 3210
External program number
Program number(BCD4 digits)
1
search
1000
0to9 0to9 0to9 0to9
External tool compensa-
Offset value(BCD 4 digits with sign)
2
tion
1001
0to7 0to9 0to9 0to9
External workpiece c oordi-
Shift value(BCD 4 digits with sign)
3 nate
system shift
1010 a
sco
e
0to7 0to9 0to9 0to9
4
External machine coordi-
nate system shift
1011 axis code
Machine coordinate system shift value(binary)
0 to 9999
Alarm No.(binary)
arm set 1100 0000
0to999
Alarm No.(binary)
arm c
ear 1100 0001
0to999
5
Message No.(binary)
per to tor message
st 1100 0100
0to999
Message No.(binary)
perator message c
ear 1100 0101
0to999
Message 1100 011 character(Character code)
Substitute No. of parts
No. of parts required(BDC4 digits)
required
1110 0000
0to9 0to9 0to9 0to9
6
Substitute No. of parts
No. of parts machined(BDC4 digits)
machined
1110 0001
0to9 0to9 0to9 0to9
WARNING
Though bits EA4 to EA6 distinguish one set of data from
another, the PMC must be interlocked in order to prevent
other function data being fed during a process for which
they are invalid.
EA3 to EA0
s
3 2 1 0
1st axis
2nd axis
3rd axis
4th axis
5th axis
6th axis
7th axis
8th axis
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
NOTE
Input an axis code according to the list below.