5. AUTOMATIC OPERAT ION
B--63003EN--1/02
436
[Classification] Input signal
[Function] Tool retraction mode is selected.
[Operation] When this signal is turned to 1, the control unit retracts the tool by a
pre--programmed distance.
[Classification] Output signal
[Function] This signal reports that tool retraction mode is set. When the control unit
is reset while the signal is 1, the signal is turned to 0, and tool retraction
mode is canceled.
[Output condition] The signal is turned to “1” when:
S Tool retraction mode is selected.
The signal is turned to “0” when:
S Tool retraction mode is not selected.
[Classification] Input signal
[Function] In tool retraction mode, a tool that has been retracted manually along an
axis is returned to the retract position along the same axis.
[Operation] When this signal is turned to “1”, the control unit traces back the path of
the manually moved tool to automatically return the tool to the retract
position.
[Classification] Output signal
[Function] This signal reports that the tool is in the retract position in tool retraction
mode. When this signal is “0”, re--positioning cannot be performed by
pressing the cycle start button.
[Output condition] The signal is set to “1” when:
S Retraction has been completed.
S The tool has been returned to the retract position.
The signal is set to “0” when:
S The tool is not in the retract position in tool retraction mode.
Signal
Tool retraction signal
TRESC<G059#0>
Tool retraction mode
signal TRACT<F092#3>
Tool return signal
TRRTN<G059#1>
Tool return completion
signal TRSPS<F092#5>