B--63003EN--1/02
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
539
[Classification] Input signal
[Function] These signals override the rapid traverse rate
[Operation] These code signals correspond to the rates as follows:
Rapid traverse override
ROV2 ROV1
verr
eva
ue
0 0 100 %
0 1 50 %
1 0 25 %
1 1 F0 %
Fo: Set in parameter No. 1421
[Classification] Input signal
[Function] Selects whether the rapid traverse override signals or the 1% step rapid
traverse override signals are enabled.
[Operation] When HROV is 1, signals *HROV0 to *HROV6 are effective and rapid
traverse override with signals ROV1 and ROV2 is ignored.
When HROV is 0, signals *HROV0 to *HROV6 are ineffective, and rapid
traverse override with signals ROV1 and ROV2 is effective.
[Classification] Input signal
[Function] Applies override to the rapid traverse rate in the range of 0% to 100% in
steps of 1%.
[Operation] These seven signals give a binary code indicating an override applied to
the rapid traverse rate.
When a binary code corresponding to an override value of 101% to
127% is specified, the override applied is clamped at 100%.
Signal
Rapid traverse override
signal
ROV1,ROV2
<G014#0, #1>
1% step rapid traverse
override selection sig nal
HROV <G096 #7>
1% step rapid traverse
override signals
*HROV0 to *HROV6
<G096 #0 to #6>