B--63003EN--1/02
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
637
#7
7501
#6
IT2
#5
IT1
#4
IT0
#3 #2 #1 #0
[Data type] Bit
IT2 IT1 IT0
0 0 0 : The interpolation period in high--speed linear
interpolation mode is 8 ms.
0 1 0 : The interpolation period in high--speed linear
interpolation mode is 4 ms.
0 0 1 : The interpolation period in high--speed linear
interpolation mode is 2 ms.
0 1 1 : The interpolation period in high--speed linear
interpolation mode is 1 ms.
1 1 1 : The interpolation period in high--speed linear
interpolation mode is 0.5 ms.
#7
7502
#6 #5 #4 #3 #2 #1 #0
SUP
[Data type] Bit
SUP 0 : Acceleration/deceleration processing is disabled in high--speed linear
interpolation mode.
1 : Acceleration/deceleration after interpolation is enabled in
high--speed linear interpolation mode.
7510 Number of controlled axes in high--speed linear interpolation mode
[Data type] Byte
[Unitofdata] Number of controlled axes
[Valid data range] 1to4
This parameter sets the number of axes controlled in high--speed linear
interpolation mode.
Series
16i/160i/18i/180i
OPERATOR’S MANUAL
(For Machining Center)
(B--63014EN)
II.19.8 High--speed linear interpolation
Parameter
Reference item