B--63003EN--1/02
1. AXIS CONTROL
53
By manual setting 1, some of the following functions and values cannot
be used, as described below. They should be used in automatic setting or
manual setting 2.
D No pulse module can be used; hence, no separate position detectors
can be used.
D No number can be skipped in parameter No. 1023; for example,
number 3 cannot be used for any axis unless number 2 is used.
D The following servo functions cannot be used:
- Learning control
- High--speed current loop
- High--speed interface axis
- Simple electronic gearbox (EGB)
Automatic settingcan be used on the FSSB setting screen, if the following
parameter is set as follows:
Bit 0 of parameter No. 1902 = 0
On the FSSB setting screen, automatic setting should be enabled by
means of the following procedure:
1. On the amplifiersetting screen, specify the axis number of a controlled
axis to be connected to each amplifier.
2. Press the [SETING] soft key. (If a warning message is displayed,
restart from step 1.)
3. On the axis setting screen, specify information about each axis, such
as a pulse module connector No.
4. Press the [SETING] soft key. (If a warning message is displayed,
repeat the procedure, starting from step 3.)
In this way, parameter Nos. 1023, 1905, 1910 to 1919, 1936, and 1937 are
set according to the results of automatic calculation. In addition, bit 1 of
parameter No. 1902 is set to 1 to indicate that each parameter has been set
up. Switching the power off then back on again causes axis setting to be
performed according to these parameter settings.
For details of the FSSB setting screen, see the FSSB data display and
setting procedure, described below.
NOTE
To use the simple electronic gearbox (EGB), perform EGB
axis setting (parameter No. 7771) before automatic setting
on the FSSB setting screen. Otherwise, automatic setting
cannot be performed correctly.
Automatic setting