B--63003EN--1/02
9. SPINDLE SPEED FUNCTION
853
#7 #6 #5 #4 #3 #2 #1 #0
SRS5200 FHD
FHD PCP
DOV
DOV
SIG
SIG
CRG
CRG
VGR
VGR
G84
G84
[Data type] Bit
G84 Method for specifying rigid tapping
0 : An M code specifying the rigid tapping mode is specified prior to the
issue of the G84 (or G74) command. (See parameter No. 5210).
1 : An M code specifying the rigid tapping mode is not used. (G84
cannot be used as a G code for the tapping cycle; G74 cannot be used
for the reverse tapping cycle.)
VGR Any gear ratio between spindle and position coder in rigid tapping
0 : Not used (The gear ratio is set in parameter No. 3706.)
1 : Used (The gear ratio is set by parameters Nos. 5221 through 5224 and
5231 through 5234.)
CRG Rigid mode when a rigid mode cancel command is specified (G80, G01
group G code, reset, etc.)
0 : Canceled after rigid mode signal RGTAP is set to 0.
1 : Canceled before rigid mode signal RGTAP is set to 0.
SIG When gears are changed for rigid tapping, the use of SIND <G032 and
G033> is
0 : Not permitted.
1 : Permitted.
DOV Override during extraction in rigid tapping
0 : Invalidated
1 : Validated (The override value is set in parameter No. 5211.)
PCP Rigid tapping
0 : Used as a high--speed peck tapping cycle
1 : Not used as a high--speed peck tapping cycle
FHD Feed hold and single block in rigid tapping
0 : Invalidated
1 : Validated
SRS To select a spindle used for rigid tapping in multi--spindle control:
0 : The spindle selection signals SWS1 and SWS2 (bits 0 and 1 of G027)
are used. (These signals are used also for multi--spindle control.)
1 : The rigid tapping spindle selection signals RGTSP1 and RGTSP2
(bits 4 and 5 of G061) are used. (These signals are provided expressly
for rigid tapping.)