APPENDIXG. ALARM LIST
B–63534EN/02
1180
Number ContentsMessage
053 TOO MANY ADDRESS COM-
MANDS
For systems without the arbitary angle chamfering or corner R cutting,
a comma was specified. For systems with this feature, a comma was fol-
lowed by something other than R or C Correct the program.
055 MISSING MOVE VALUE IN CHF/
CNR
In the arbitrary angle chamfering or corner R block, the move distance
is less than chamfer or corner R amount.
058 END POINT NOT FOUND In a arbitrary angle chamfering or corner R cutting block, a specified axis
is not in the selected plane. Correct the program.
059 PROGRAM NUMBER NOT FOUND In an external program number search, a specified program number
was not found. Otherwise, a program specified for searching is being
edited in background processing. Alternatively, the program with the
program number specified in a one–touch macro call is not found in
memory. Check the program number and external signal. Or discontin-
ue the background eiting.
060 SEQUENCE NUMBER NOT FOUND Commanded sequence number was not found in the sequence number
search. Check the sequence number.
070 NO PROGRAM SPACE IN
MEMORY
The memory area is insufficient.
Delete any unnecessary programs, then retry.
071 DATA NOT FOUND The address to be searched was not found. Or the program with speci-
fied program number was not found in program number search.
Check the data.
072 TOO MANY PROGRAMS The number of programs to be stored exceeded 63 (basic), 125 (option),
200 (option), or 400 (option). Delete unnecessary programs and
execute program registeration again.
073 PROGRAM NUMBER ALREADY IN
USE
The commanded program number has already been used.
Change the program number or delete unnecessary programs and
execute program registeration again.
074 ILLEGAL PROGRAM NUMBER The program number is other than 1 to 9999.
Modify the program number.
075 PROTECT An attempt was made to register a program whose number was pro-
tected.
076 ADDRESS P NOT DEFINED Address P (program number) was not commanded in the block which
includes an M98, G65, or G66 command. Modify the program.
077 SUB PROGRAM NESTING ERROR The subprogram was called in five folds. Modify the program.
078 NUMBER NOT FOUND A program number or a sequence number which was specified by ad-
dress P in the block which includes an M98, M99, M65 or G66 was not
found. The sequence number specified by a GOTO statement was not
found. Otherwise, a called program is being edited in background pro-
cessing. Correct the program, or discontinue the background editing.
079 PROGRAM VERIFY ERROR In memory or program collation,a program in memory does not agree
with that read from an external I/O device. Check both the programs in
memory and those from the external device.
080 G37 ARRIVAL SIGNAL NOT AS-
SERTED
In the automatic tool length measurement function (G37), the measure-
ment position reach signal (XAE, YAE, or ZAE) is not turned on within
an area specified in parameter 6254 (value ε).
This is due to a setting or operator error.
081 OFFSET NUMBER NOT FOUND IN
G37
Tool length automatic measurement (G37) was specified without a H
code. (Automatic tool length measurement function) Modify the pro-
gram.
082 H–CODE NOT ALLOWED IN G37 H code and automatic tool compensation (G37) were specified in the
same block. (Automatic tool length measurement function) Modify the
program.
083 ILLEGAL AXIS COMMAND IN G37 In automatic tool length measurement, an invalid axis was specified or
the command is incremental. Modify the program.