3.SPECIFICATIONS SVM B-65322EN/02
- 20 -
Installation and connection of A06B-6130-H401
WARNING
1 Regenerative discharge resistors may become very hot (100 to 200 °C). Be
careful not to touch them.
2 Before touching a regenerative discharge resistor, for example, for maintenance
purposes, turn off all power to the amplifier, wait for at least 30 minutes, and make
sure that the DC link charge indicator LED (CAUTION CHARGE) is off and the
regenerative resistor is sufficiently cold.
3 When mounting a regenerative resistor, keep it sufficiently far from any flammable.
4 The minimum clearance between the regenerative resistor and the wall should be
10 mm.
To connector CZ7
To connector CXA20