11. PROGRAM COMMAND
B–63503EN–1/01
548
#7 #6 #5 #4 #3 #2 #1 #0
0100 CTV
Setting entry is acceptable.
[Data type] Bit
CTV: Character counting for TV check in the comment section of a program.
0 : Not performed
1 : Performed
#7 #6 #5 #4 #3 #2 #1 #0
3201 NPE N99
[Data type] Bit
N99 With an M99 block, when bit 6 (NPE) of parameter No. 3201 = 0, program
registration is assumed to be:
0 : Completed
1 : Not completed
NPE With an M02, M30, or M99 block, program registration is assumed to be:
0 : Completed
1 : Not completed
#7 #6 #5 #4 #3 #2 #1 #0
3404 EOR SBP
[Data type] Bit
SBP Address P of the block including M198 in the subprogram call function
0 : Indicating a file number
1 : Indicating a program number
EOR When the endĆofĆrecord mark (%) is read during program execution:
0 : P/.S alarm No. 5010 occurs.
(Automatic operation is stopped, and the system enters the alarm
state.)
1 : No alarm occurs.
(Automatic operation is stopped, and the system is reset.)
6030 M code that calls the program entered in file
[Data type] Byte
[Valid data range] 0, and 1 to 255
When the subprogram call function is used, this parameter sets the M code
for calling a program in a file stored on the external input/output device.
NOTE
The M code is judged to be M198 when zero is specified as
the setting value.
Parameter