11. PROGRAM COMMAND
B–63503EN–1/01
550
Either inch or metric input can be selected by G code.
[Classification] Output signal
[Function] This signal indicates that inch input mode is in progress.
[Output condition] “1”indicates that the inch input mode (G20) is in progress, and “0”
indicates that metric input mode (G21) is in progress.
This signal changes to the corresponding state when modes are switched
using the setting data display on the MDI panel.
#7 #6 #5 #4 #3 #2 #1 #0
F002 INCH
#7 #6 #5 #4 #3 #2 #1 #0
0000 INI
Setting entry is acceptable.
[Data type] Bit
INI Unit of input
0: In mm
1: In inches
#7 #6 #5 #4 #3 #2 #1 #0
1001 INM
NOTE
When this parameter is set, the power must be turned off
before operation is continued.
[Data type] Bit
INM Least command increment on the linear axis
0 : In mm (metric system machine)
1 : In inches (inch system machine)
11.4
INCH/METRIC
CONVERSION
General
Signal
Inch input signal
INCH<F002#0>
Signal address
Parameter