B–63683EN/01
5. TOOL FUNCTION (T FUNCTION)
103
#7
G248
#6 #5 #4 #3 #2 #1
BTFIN
#0
#7
F232
#6 #5 #4 #3 #2 #1
BTF
#0
#7
BT07F246
#6
BT06
#5
BT05
#4
BT04
#3
BT03
#2
BT02
#1
BT01
#0
BT00
#7
BT15F247
#6
BT14
#5
BT13
#4
BT12
#3
BT11
#2
BT10
#1
BT09
#0
BT08
#7
BT23F248
#6
BT22
#5
BT21
#4
BT20
#3
BT19
#2
BT18
#1
BT17
#0
BT16
#7
BT31F249
#6
BT30
#5
BT29
#4
BT28
#3
BT27
#2
BT26
#1
BT25
#0
BT24
#7
16260
#6 #5 #4 #3 #2 #1
BST
#0
[Data type] Bit
BST The function used to output a T code beforehand is:
0 : Disabled.
1 : Enabled.
1. In MDI mode, a single block is issued in advance.
2. Manual operation intervention is not possible.
3. The operation can be resumed after feed hold, but not after the
following:
D Program number search, sequence number search
D Finding the beginning of a program
D Editing
4. If an M code that must not be buffered is specified, subsequent T codes
are not pre–issued before the M code has been executed.
G90 G00 X1000. Y1000. ;² Current block
M00 ;
G72 X100. Y100. ;
G26 I10. J0 K4 T600 ; ² Output only after M00 is executed
Signal address
Parameter
Limitations