B–63683EN/01
9. SAFETY ZONE AREA EXTENSION
159
16534 Number of zones to be detected for automatic setting
[Data type] Byte
[Unit of data] Piece
[Valid data range] 0 to 8
16930 Positive X coordinate for safety zone 5
16931 Negative X coordinate for safety zone 5
16932 Y coordinate for safety zone 5
16933 Positive X coordinate for safety zone 6
16934 Negative X coordinate for safety zone 6
16935 Y coordinate for safety zone 6
16936 Positive X coordinate for safety zone 7
16937 Negative X coordinate for safety zone 7
16938 Y coordinate for safety zone 7
16939 Positive X coordinate for safety zone 8
16940 Negative X coordinate for safety zone 8
16941 Y coordinate for safety zone 8
[Data type] Two–word
Increment system IS–A IS–B Unit
Millimeter machine 0.01 0.001 mm
Inch machine 0.001 0.0001 inch
[Valid data range] 0 to "99999999
Each set of the parameters specify safety zone 5, 6, 7, or 8.
NOTE
1 The values set for zone #n must be smaller than those set
for zone #n + 1. (n: 1 to 8)
2 Zeros must be specified for zones which need not be
specified.
[Unit of data]