B. ALARM LIST
B–63683EN/01
APPENDIX
210
Number ContentsMessage
4549 ILLEGAL TOOL DATA FORMAT The size of the registered tool data patterns has exceeded the upper lim-
it of 16KB.
4600 T, C COMMAND IN
INTERPOLATION
In the linear interpolation (G01) mode or circular interpolation (G02,
G03) mode, a T command or C–axis command was specified.
4601 INHIBITED T, M COMMAND In the block of G52, G72, G73, or G74, a T or M command was specified.
4602 ILLEGAL T–CODE The specified T command is not cataloged on the tool register screen.
4603 C AXIS SYNCHRONOUS ERROR The difference between the position deviation value of C1 axis and C2
axis exceeds the parameter value (No. 16364, 16365) with the C–axis
synchronous control function.
4604 ILLEGAL AXIS OPERATION A C–axis command was specified in the block containing a T command
for multiple tools.
4605 NEED ZRN The C–axis synchronization is not done normally.
4606 INHIBITED T COMMAND A T command was specified during normal line control.
4630 ILLEGAL COMMAND IN LASER
MODE
In the laser mode, a nibbling command or pattern command was speci-
fied.
4650 IMPROPER G–CODE IN OFFSET
MODE
In the cutter compensation mode, an inhibited G code (pattern com-
mand, G73, G74, G75, etc.) was specified.
4700 PROGRAM ERROR (OT +) The value specified in the X–axis move command exceeded the posi-
tive value of stored stroke limit 1. (Advance check)
4701 PROGRAM ERROR (OT –) The value specified in the X–axis move command exceeded the nega-
tive value of stored stroke limit 1. (Advance check)
4702 PROGRAM ERROR (OT +) The value specified in the Y–axis move command exceeded the posi-
tive value of stored stroke limit 1. (Advance check)
4703 PROGRAM ERROR (OT –) The value specified in the Y–axis move command exceeded the nega-
tive value of stored stroke limit 1. (Advance check)
4704 PROGRAM ERROR (OT +) The value specified in the Z–axis move command exceeded the positive
value of stored stroke limit 1. (Advance check)
4705 PROGRAM ERROR (OT –) The value specified in the Z–axis move command exceeded the nega-
tive value of stored stroke limit 1. (Advance check)