3. PERIPHERAL EQUIPMENT CONTROL
B--65245EN/02
HANDLING
86
When the overtravel alarm is issued, a gradual stop occurs, and the
speed control mode is terminated. When the external reset signal
ERS (Yy+1#0) is set to 1, a gradual stop occurs, and the speed control
mode is terminated. When the interlock signal *ILK (Yy+1#3) is set
to 0, a gradual stop occurs. When the interlock signal is set to 1 again,
acceleration is performed to restart a movement.
When the servo--off command signal SVFX (Yy+1#2) is set to 1, a
gradual stop occurs, and the speed control mode is terminated.
(3) The states of input signals in the speed control mode are described
below.
Follow--up is performed for position updating, so that the axis
movement in--progress signal M VX (Xx+7#2) and the distribution
pulse signal IPLX (Xx+0#1) are set to 1.
During movement in one direction, the movement direction signal
MVDX (Xx+7#0) is set to 1.
The automatic operation signal OP (Xx+1#7) and the automatic
operation start in --progress signal STL (Xx+1#5) are set to 1.
Clamp/unclamp control is disabled in the speed control mode, so that
the unclamp command signal UCPC2 (Xx+1#4) is not set t o 1.