3. PERIPHERAL EQUIPMENT CONTROL
B--65245EN/02
HANDLING
90
Rewriting being
performed
ST
OPC1
OPC4
No. LED indication Description Action
250
Input data 1 is invalid. Check the specified value of input data 1 of a
function code command.
251
Input data 2 is invalid. Check the specified value of input data 2 of a
function code command.
254
Function code is invalid. Check the specified value of function code of
a function code command.
#7 #6 #5 #4 #3 #2 #1 #0
004 NEPRM
Size : 1 byte/bit type
Standard value :0
NEPRM When the peripheral equipment control parameter rewrite
function is executed, writing to the EEPROM (memory
for holding parameters) is:
0 : Performed.
1 : Not performed.
CAUTION
1 For an application that rewrites parameters frequently with
the peripheral equipment control parameter rewrite
function, set this parameter to 1.
2 The setting of this parameter is applicable to the rewriting
of parameters using a direct command.
3.4.8.4
Command timing chart
3.4.8.5
Alarm
3.4.8.6
Parameter