B. PARAMETERS
B--65245EN/02
APPENDIXES
192
020 Response data specification (PHOUT)
Size : 1 byte
Standard value :3
PHOUT Specifies whether or what to output as response data
(Xx+3 to Xx+6), as follows:
0 : Nothing is output.
1 : An ATC and point No. are output if an ATC cycle and
point positioning are i nvolved.
2 : The machine coordinate is output in real time.
3 : The workpiece coordinate is output in real time.
4 : The motor current value is output. The motor current
value means the maximum current value of the
amplifier in 6554.
NOTE
If the motor current value is output as response data, set
LDM (bit 6 of parameter No. 005) to “1” and set “4” for
parameter No. 020.
022 ECF and EBSY signal minimum output time
Size : 1 byte
Unit :8ms
Range : 0 to 127
Standard value :5
Description : Specifies the minimum output time for the ECF and
EBSY signals (direct command interface control flag
2). This is valid when the power mate CNC manager
is used.
023 PMM allocation rate assumed when reading continuous data with a direct
command
Size : 1 byte
Range : 0 to 100
Standard value :50
Do not change the parameter from its standard value.
029 Internal variable
Size : 1 byte
Do not change the value of the parameter.
062 External pulse input--based axis movement amount ratio setting 1 (M)
063 External pulse input--based axis movement amount ratio setting 2 (N)
Size : 2 bytes
Unit :8ms
Range : 1 to 32767
Standard value :1
Description : Specify a ratio M/N for an axis movement amount
based on an external pulse input.