B--65245EN/02
B. PARAMETERSAPPENDIXES
203
087 Current compensation 5 (DETQLM)
Size : 2 bytes
Valid data range : 0 to 32767
Do not change the s tandard setting.
088 Current compensation 6 (NINTCT)
Size : 2 bytes
Valid data range : 0 to 32767
Do not change the s tandard setting.
089 Current compensation 7 (MFWKCE)
Size : 2 bytes
Valid data range : 0 to 32767
Do not change the s tandard setting.
090 Current compensation 8 (MFWKBL)
Size : 2 bytes
Valid data range : 0 to 32767
Do not change the s tandard setting.
091 VCMD polyline speed (P_VCLN)
Size : 2 bytes
Unit :0.01rpm
Valid data range : 0 to 32767
Setting the parameter t o a positive value enables the VCMD polyline
function. If the actual speed of the m otor is lower than the speed specified
in this parameter, the position loop gain is doubled, thus accelerating
positioning.
092 Low--speed integration threshold speed (P_LVIN)
Size : 2 bytes
Unit :0.01rpm
Valid data range : 0 to 32767
When the low--speed integration function is enabled, if the actual motor
speed becomes higher than the speed specified in this parameter, the speed
loop integration item becomes 0.
100 Load inertia ratio (LDINT)
Size : 2 bytes
Valid data range : 0 to 1024
This parameter specifies the ratio of the machine load inertia to the motor
inertia using a value calculated with the following formula as a guideline:
Load inertia ratio = ×256
Machine load inertia
Motor inertia