B-65245EN/02-8
2/11
EDIT
DATE DESIG.
DESCRIPTION
FANUC SERVO MOTOR β series I/O Link Option
Skip Function (Improvement of the specification) and
CAUTION to the parameters No.068, 141
TITLE
DRAW.NO. CUST.
SHEET
01
04.05.06
Newly added
Group Signal name Symbol Address Referenc
e
15 Skip signal
HDI
Direct input 2.3.15
Please add the following description after the explanation 15 about “*DEC” in the
subsection 2.2 SIGNALS (LISTED IN GROUPS) of II HANDLING 2. SIGNAL DESCRIPTION.
Please replace “the table of Response data check signals DSP1 and DSP2” and the note
in the subsection “2.3.13 Peripheral Equipment Control Function Code and Related
Information” of II HANDLING 2. SIGNAL DESCRIPTION with the followings.
DSP2 DSP1 Response data
1
1 Coordinate, current of motor
or measuring data by skip function
1 0
Current position number (ATC point
number)
NOTE
The distinction among coordinate, current of motor and measuring
data by skip function depends on the setting value of the paramete
No.20.