Panel Mount Type 3.5" Floppy Disk Unit for Fanuc MMC-IV and IT Connect. Manual (A-71385E/03) Additional Manual Page 1

Additional Manual
TECHNICAL REPORT (MANUAL) No.TMN98/107E
Date 1998,Aug.21
General Manager of
Hardware Laboratory
PANEL MOUNT TYPE 3.5” FLOPPY DISK UNIT
FOR FANUC MMC-IV AND INTELLIGENT TERMINAL CONNECTING MANUAL
1. Communicate this report to:
Your information only
GE Fanuc-N, GE Fanuc-E
FANUC Robotics
CINCINNATI MILACRON
Machine tool builder
Sales agency
End user
2. Summary for Sales Documents
(Sales guide, Functional comparison list, etc.)
3. Notice
There were misleading expressions in the previous editions of this manual. These
expressions are modified in this edition.
4. Attached Document
Drawing
No.
PANEL MOUNT TYPE 3.5” FLOPPY DISK UNIT
FOR FANUC MMC-IV AND INTELLIGENT
TERMINAL CONNECTING MANUAL
A-71385E EDITION 03 (2/13~13/13)
Original section of issue
General
Manager
Department
Manager
Section
Manager
Person in
Charge
IDE

Contents Summary of Panel Mount Type 3.5" Floppy Disk Unit for Fanuc MMC-IV and IT Connect. Manual (A-71385E/03) Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) No.TMN98/107E Date 1998,Aug.21 General Manager of Hardware Laboratory PANEL MOUNT TYPE 3.5” FLOPPY DISK UNIT FOR FANUC MMC-IV AND INTELLIGENT TERMINAL CONNECTING MANUAL 1. Communicate this report to: Your information only ○ GE Fanuc-N, GE Fanuc-E FANUC Robotics CINCINNATI M
  • Page 2PANEL MOUNT TYPE 3.5" FLOPPY DISK UNIT FOR FANUC MMC-IV AND INTELLIGENT TERMINAL CONNECTING MANUAL 1. Type of applied technical documents Name Spec. No./Version 2. Summary of Change Group Name / Outline New,Add, Applicable Correct, Date Delete Basic Function Optional Function Unit PANEL MOUNT TYPE 3
  • Page 3PANEL MOUNT TYPE 3.5" FLOPPY DISK UNIT FOR FANUC MMC-IV AND INTELLIGENT TERMINAL CONNECTING MANUAL ------------Contents------------ 1. Specification 1.1. Outline 1.2. Ordering Specification 1.3. Environmental Requirements (1) Dust (2) Temperature 1.4. Caution on Operating 1.5. Mounting Direction 1.6
  • Page 41. Specification 1.1. Outline This Panel Mount Type 3.5” Floppy Disk Unit is usable for FANUC MMC- (from now on it is MMC- for short) and Intelligent Terminal (IT), and one drive is mounted in this unit. By connecting with MMC-IV or IT • A floppy disk formatted as 1.44MB or 720kB by IBM-PC can be re
  • Page 51.5. Mounting Direction 1.6. Appearance 4-M3 134 140 64 (HOLE) 70 5 4-φ3.6 PANEL CUT J2 FDD 150 140 ACRYLIC 104 J1 WINDOW 1.6 145 5 5 70 5 80 TITLE Panel Mount Type 3.5” Floppy Disk Unit for FANUC MMC-Ⅳ AND INTELLIGENT TERMINAL Connecting Manual DRAW. NO. CUST. A-71385E EDIT. DATE DESIG. DESCRIPTION
  • Page 62. Connecting (MMC-IV) 2.1. Connector MMC-IV P.C.B FLOPPY DISK UNIT JD8 CONNECTOR FDD ISA EXTENDED UNIT CNC CONTROL UNIT NOTE 1) ISA extended unit is an additional option. TITLE Panel Mount Type 3.5” Floppy Disk Unit for FANUC MMC-Ⅳ AND INTELLIGENT TERMINAL Connecting Manual DRAW. NO. CUST. A-71385E
  • Page 72.2. Connecting Panel Mount Type 3.5” MMC-IV P.C.B. Floppy Disk Unit HONDA TSUSHIN JD8 (PCR-E50LMDET) PCR-E50FS(Connector) J1(PS-34PE-D4LT1-PN1,JAE) 1 *DSKC 26 HDSEL for solder paste 1 0V 2 DENSE 2 0V 27 0V till #20AWG 3 0V 4 *INUSE 3 *WPRT 28 *TRK0 PCR-E50FA(Connector) 5 0V 6 - 4 0V 29 0V for press
  • Page 82.4. Cable Connecting JD J1 1 34 *DSKCH *DSKCH 2 33 0V 0V 3 28 *WP RT *WP RT 4 27 0V 0V 5 22 *WDATA *WDATA 6 21 0V 0V 7 16 *MTRON *MTRON 8 15 0V 0V 9 10 *DS0 *DS0 10 9 0V 0V 11 30 *RDATA *RDATA 12 29 0V 0V MMC-IV 13 24 *WE *WE P a n el Mou n t Type 14 23 P .C.B. 0V 0V 3.5" F loppy Disk 15 18 *DIR *D
  • Page 93 4. Connecting (Intelligent Terminal) 3 4.1. Connector Back View J J J D D D 3 3 9 4 3 CP5 COP CD32 CD34 CN2 Print Function CD34 Floppy Disk Drive, Signal CN2 Floppy Disk Drive, Power source output TITLE Panel Mount Type 3.5” Floppy Disk Unit for FANUC MMC-Ⅳ AND INTELLIGENT TERMINAL Connecting Manu
  • Page 103 4.2. Connecting Panel Mount Type 3.5” Intelligent Terminal Floppy Disk Unit CD3 J1 1 0V 2 DE NSE (P S-34P E -D4LT1-N1,J AE ) 3 0V 4 1 0V 2 DE NSE L 5 0V 6 3 0V 4 *INUSE 7 0V 8 *INDE X 5 0V 6 9 0V 10 *MT0 7 0V 8 *INDE X 11 0V 12 *DS1 YAMAICH I 9 0V 10 *DS0 13 0V 14 *DS0 E LE CTRIC 11 0V 12 *DS1 15
  • Page 113 4.4. Cable Connecting J D8 J1 1 1 0V 0V 2 2 DENSEL DENSEL 3 3 0V 0V 4 4 (NC) (NC) 5 5 0V 0V 6 6 (NC) (NC) 7 7 0V 0V 8 8 *INDEX *INDEX 9 9 0V 0V 10 16 *MT0 *DS0 11 15 0V 0V 12 14 *DS1 *DS1 13 13 0V 0V 14 12 *DS0 (Reser ve) 15 11 0V 0V 16 10 In t elligen t *MT1 *MTRON 0V 17 17 0V P a n el Moun t typ
  • Page 124 3. Notice in using for Intelligent Terminal This Panel Mount Type 3.5” Floppy Disk Unit is usable on FANUC Intelligent Terminal, too. Please take care of the follows in that case. 4 3.1. Changes the setting of plugs The setting of plugs on the Floppy Disk Unit has to be changed as follows accordin
  • Page 13(i) In case of YD-702D (A87L-0001-0171) (3) for MMC-IV for In t elligen t Ter m in a l (Set t in g of A02B-0207-C005) (Set t in g of A02B-0207-C006) T2 DS0 T2 DS0 DS1 DS1 RY RY DC IF DC IF H2 ‥‥Open H2 H4 ‥‥Sh or t H4 DS2 DS2 4 3. 2. Cable specification Please use the following cable in connecting t