2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 130 -
- Action
NoAction:
Check this check box to disable the button control function.
The control can be placed on the form, but can be disabled, in
which case the display is embedded.
Set the button image for no action set in the Image tab.
Switch Type:
Select a switch type. This property is valid for other than screen
switch action.
Action Type:
Specify operations to be performed when a switch is pressed and
released. Click the Detail button and set the detailed properties of
the selected type.
For the method of setting, see [Action Detail Properties].
[Bit Set]
Performs bit operation in the PMC area.
[Data Set]
Writes fixed data as word-size data to the PMC area.
[Function Call]
Calls an FP function.
[Change Screen]
Calls another screen. (Used with momentary type)
[History Display]
Switches between the history message display control
screens.