2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 202 -
- Action
No Action:
Check this check box to disable the function of the
numeral/character string indication control.
The control can be placed on the form, but can be disabled, in
which case the display is embedded.
Set the embedded image for no action set in the Image tab.
Action Type:
Choose whether to display the value of a PMC area or call an FP
function.
0: PMC
1: Function
Watch PMC Area:
Specify a type of PMC address to be referenced. The following
areas can be specified:
R, D, K, X, Y, G, F, E(PMC-SB7)
Watch Address:
Specify a PMC address to be referenced.
Function Name:
Specify a function to be called when 1 (Function) is selected in
Action Type.
* For argument setting, see Chapter 3, “FP Functions.”