2.DEVELOPMENT OF CUSTOM SCREEN B-66284EN/01
- 280 -
Creating lamp display child screens
An example of creating lamp display child screens is provided
below.
The method of creating lamp display child screens is basically
the same as for creation of coordinate display child screens.
Based on the copy source child screen (COP_lamp_CNC.xml),
make additional copies of the machine lamp display child screen
(COP_lamp_MCN.xml) and the program display child screen
(COP_lamp_PRG.xml).
Set the ON/OFF colors, captions, and signals to be turned on for
the lamps placed on each child screen.
For each lamp not used, check the disable property check box on
the action tab. A lamp processed in this way is treated simply as
a label indication. If the assignment of a lamp is needed later, the
property for enabling use as a lamp may be set.
.xml name
Control
name
Object ID Tab/Property name Setting/Change/Point
Character/ on/off Caption Specify the character of lamp name
Action/NoAction
When not using
→
Action/Wath PMC Lighting signal address of lamp
Action/Blink Signal Blinking signal address of lamp(Opt.)
FPLamp
FPLamp1
to
FPLamp15
Image/ on/off Color Setting of on/off color,ETC
Action/Screen Type Sub Screen
COP_lamp_CNC
TFPChgScrn TFPChgScrn1
Action/Screen Name COP_lamp_MCN
Character/ on/off Caption Specify the character of lamp name
Action/NoAction
When not using
→
Action/Wath PMC Lighting signal address of lamp
Action/Blink Signal Blinking signal address of lamp(Opt.)
FPLamp
FPLamp1
to
FPLamp15
Image/ on/off Color Setting of on/off color,ETC
Action/Screen Type Sub Screen
COP_lamp_MCN
TFPChgScrn TFPChgScrn1
Action/Screen Name COP_lamp_PRG
Action/Action Type
1:Function (Running program
indication)
FpNDisp FpNDisp1
Action/Function name rdexecprog[0_99_0]
Action/Screen Type Sub Screen
COP_lamp_PRG
TFPChgScrn TFPChgScrn1
Action/Screen Name COP_lamp_CNC
Display sub screen of
Sub screen for lamp display Sub screen for lamp display
power supply turning on
related to CNC
related to machine
Sub screen for program