B-70265EN/02 APPENDIX E.PARAMTER LIST
- 277 -
15093 Power control constant
[Data type] Word
[Unit of data] %
[Valid data range] 0 to 100
Set the power control constant.
15094 Power control filter time constant
[Data type] Word
[Unit of data] msec
[Valid data range] 0 to 32767
Set the power control filter time constant.
15095 Allowable variation in power control speed
[Data type] Byte
[Unit of data] mm/min (specified increment for B8F1-08 or earlier) or %
[Valid data range] 0 to 255
[Standard setting value] 4
Set the amount by which the power control speed is allowed to vary.
This parameter is valid when parameter No. 15450 is set to 0.
To set a value of 256 or greater, use parameter No. 15450.
Set this parameter according to the setting of bit 6 of parameter No.
15096 (SDB) as follows.
#7 #6 #5 #4 #3 #2 #1 #0
15096 EGM SDB FOV SQ0 PCD PCF PCP
[Data type] Bit
PCP
0: Does not control the output according to the feedrate in power
control.
1: Controls the output according to the feedrate in power control.
PCF
0: Does not control the frequency according to the feedrate in
power control.
1: Controls the frequency according to the feedrate in power
control.
PCD
0: Does not control the duty ratio according to the feedrate in
power control.
1: Controls the duty ratio according to the feedrate in power
control.
SQ0 When 0 is specified for the peak power (S) or pulse duty ratio (Q), the
power control function is:
0: Executed.
1: Stopped.