OPERATION
4. AUTOMATIC OPERATION
B–63664EN/02
498
Procedure for program restart by specifying a block number (P and Q types)
1 Retract the nozzle and perform the required operations (such as
replacement of the nozzle). Change the offset value if required. (Go to
Procedure 2.)
1 When the power is turned on or an emergency stop is released,
perform the required operations at that time, including reference
position return.
2 Move the machine manually to the programmed start point
(processing start point) and set the modal data and coordinate system
under the same conditions as those at processing start.
3 If required, change the offset value. (Go to Procedure 2.)
1 Set the program restart switch on the machine operator’s panel to the
ON position.
2 Press the
PROG
function key to display the program to be restarted.
3 Find the start of the program. Press the
RESET
key.
4 Enter the number of the block from which the program is to be
restarted, then press the [P TYPE] or [Q TYPE] soft key. The block
number can consist of up to eight digits.
Procedure 1
[ P TYPE ]
[ Q TYPE ]
Procedure 2
[Common to P and Q types]
B
f f f f f f f f
Block number
[P TYPE]
or
[Q TYPE]