OPERATIONB–63664EN/02 8. DATA INPUT/OUTPUT
589
Parameters can be input and output using the ALL IO screen.
Inputting parameters
1 Press soft key [PARAM] on the ALL IO screen, described in Section
8.10.1.
2 Select EDIT mode.
3 Press soft key
[(OPRT)]. The screen and soft keys change as shown
below.
READ/PUNCH (PARAMETER) O1234 N12345
MDI
*
* * * * * * * * * * * *
12:34:56
READ PUNCH
I/O CHANNEL 3 TV CHECK OFF
DEVICE NUM. 0 PUNCH CODE ISO
BAUDRATE 4800 INPUT CODE ASCII
STOP BIT 2 FEED OUTPUT FEED
NULL INPUT (EIA) NO EOB OUTPUT (ISO) CR
TV CHECK (NOTES) ON BAUDRATE CLK. INNER
CD CHECK (232C) OFF RESET/ALARM ON
PARITY BIT OFF COM CODE ASCII
END CODE EXT COM PROTCOL A
INTERFACE RS422 SAT COMMAND HOST
(0:EIA 1:ISO)>1_
4 Press soft key [READ], then [EXEC].
The parameters are read, and the ”INPUT” indicator blinks at the
lower–right corner of the screen. Upon the completion of input, the
”INPUT” indicator is cleared from the screen.
To cancel input, press soft key
[CAN].
8.10.3
Inputting and
Outputting Parameters
Procedure
EXECCAN