4. DESCRIPTION OF PARAMETERS
B–63010EN/02
10
#7
0002
#6 #5 #4 #3 #2 #1 #0
RDG
RDGSJZ
Setting entry is acceptable.
[Data type] Bit
RDG Remote diagnosis is
0: Not performed.
1: Performed.
To use an RS–232C serial port for performing remote diagnosis, connect
and setup the modem, cable, and the like, then set 1 in this parameter. When
using a modem card, the setting is not necessary.
SJZ Manual reference position si performed as follows:
0 : When no reference position has been set, reference position return is
performed using deceleration dogs. When a reference position is
already set, reference position return is performed using rapid traverse
and deceleration dogs are ignored.
1 : Reference position return is performed using deceleration dogs at all
times.
Note
SJZ is enabled when bit 3 (HJZ) of parameter No.1005 is
set to 1. When a reference position is set without a dog,
(i.e. when bit 1 (DLZ) of parameter No.1002 is set to 1 or
bit 1 (DLZx) of parameter No.1005 is set to 1) reference
position return after reference position setting is
performed using rapid traverse at all times, regardless of
the setting of SJZ.
#7
RMVx0012
#6 #5 #4
AIC
#3 #2 #1 #0
MIRx
RMVx MIRx
Setting entry is acceptable.
[Data type] Bit axis
MIRx Mirror image for each axis
0 : Mirror image is off.
1 : Mirror image is on.
AIC The travel distance of an axis command is:
0: Determined by the value specified with the address.
1: Always handled as an incremental value.
RMVx Releasing the assignment of the control axis for each axis
0 : Not released
1 : Released
NOTE
RMVx is valid when RMBx in parameter 1005#7 is 1.