4. DESCRIPTION OF PARAMETERS
B–63010EN/02
286
5344
Position control loop gain for the spindle and tapping axis in rigid tapping using
the third spindle (common to all the gears)
5345
Position control loop gain for the spindle and tapping axis in rigid tapping using
the third spindle (first–stage gear)
5346
Position control loop gain for the spindle and tapping axis in rigid tapping using
the third spindle (second–stage gear)
NOTE
After these parameters have been set, the power must be
turned off then back on for the settings to become effective.
[Data type] Word
[Unit of data] 0.01 s
–1
[Valid data range] 1 to 9999
Each of these parameters is used to set a position control loop gain for the
spindle and tapping axis in rigid tapping using the third spindle.
NOTE
1 To use a varied loop gain on a gear–by–gear basis, set
parameter No.5344 to 0, and set a loop gain for each gear
in parameters No.5345 and No.5346.
2 This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.
5350
Positional deviation limit imposed during tapping axis movement in rigid tapping
using the second spindle
[Data type] 2–word
[Unit of data] Detection unit
[Valid data range] 1 to 99999999
This parameter sets a positional deviation limit imposed during tapping
axis movement in rigid tapping using the second spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.
5351
Positional deviation limit imposed during spindle movement in rigid tapping using
the second spindle
[Data type] Word
[Unit of data] Detection unit
[Valid data range] 1 to 32767
This parameter is used to set a positional deviation limit imposed during
spindle movement in rigid tapping using the second spindle.
NOTE
This parameter is enabled when the SPR parameter (bit 1 of
parameter No.5204) is set to 1.