4. DESCRIPTION OF PARAMETERS
B–63010EN/02
76
1460
Upper limit of feedrate for the one–digit F code command (F1 to F4)
1461
Upper limit of feedrate for the one–digit F code command (F5 to F9)
[Data type] 2–word
[Unit of data]
[Valid data range]
Valid data range
ncremen
sys
em
n
o
a
a
IS-A, IS-B IS-C
Millimeter machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotaion axis 1 deg/min 6 to 15000 6 to 12000
Set the upper limit of feedrate for the F1-digit feed command.
As the feedrate increases by turning the manual pulse generator, the
feedrate is clamped when it reaches the upper limit set. If an F1-digit feed
command F1 to F4 is executed, the upper limit is that set in parameter
1460. If an F1-digit command F5 to F9 is executed, the upper limit is that
set in parameter 1461.
1465
Virtual radius for feedrate control about rotation axis
[Data type] 2–word
[Unit of data]
Increment system IS–A IS–B IS–C Unit
Metric input mm
Inch input
0.01 0.001 0.0001
inch
[Valid data range] 0 to 99999999